Huawei H19-402_V1.0 exam is an important certification for IT professionals who want to specialize in data center network planning and design. With its comprehensive coverage of key topics and its focus on practical skills and knowledge, H19-402_V1.0 exam is an excellent way to demonstrate your expertise and advance your career in the IT industry.
Huawei H19-402_V1.0 (HCSP-Presales-Data Center Network Planning and Design V1.0) Certification Exam is a must-have certification for professionals who are involved in the planning and design of data center networks. HCSP-Presales-Data Center Network Planning and Design V1.0 certification is recognized globally and is highly valued by employers in the ICT industry. It demonstrates that the holder has the skills and knowledge required to plan and design data center networks that meet the requirements of modern businesses, and it also demonstrates that the holder has a deep understanding of the latest trends and best practices in data center network planning and design.
NEW QUESTION # 151
Which of the following is the minimum ambient temperature used by FusionModule800 and FusionModule500?
- A. -40 ℃
- B. -20 ℃
- C. Below -40 ℃
- D. 0 ℃
Answer: A
NEW QUESTION # 152
When choosing a 300mm air conditioner, you need to choose a 300mm control skylight
- A. False
- B. True
Answer: A
NEW QUESTION # 153
The output power factor of UPS5000-A-400/500K is (), which adapts to new IT loads and significantly improves the system's load capacity.
- A. 0.8
- B. 0.95
- C. 0
- D. 0.9
Answer: C
NEW QUESTION # 154
What functions does the iCooling feature of FusionModule2000 V3.0 include? (Multiple choice)
- A. Refrigerant capacity alarm function
- B. AI self-optimization algorithm, air conditioning energy saving 8%
- C. Refrigeration system visualization
- D. Temperature cloud map and air conditioning linkage
Answer: A,B,C,D
NEW QUESTION # 155
What factors are currently affecting the application of HVDC equipment in the machine room?
(Multiple choice)
- A. Not all loads can be powered directly by DC
- B. Too low efficiency
- C. The cost of DC switching devices is relatively high
- D. The standard is not perfect, and multiple 240V/336V systems coexist
Answer: A,B,C,D
NEW QUESTION # 156
Which of the typical configurations of FusionModule500 are standard?
- A. Flood, smoke, SMS alert, video
- B. Water immersion, smoke detection, temperature and humidity, door magnet
- C. Water immersion, smoke detection, temperature and humidity, mobile phone APP
Answer: B
NEW QUESTION # 157
When multiple FusionModule products are used in the same project, which one should be selected for the associated application scenario when configuring NetEco?
- A. FusionModule5000
- B. FusionModule2000
- C. Related FusionModule Series
- D. Customization
Answer: D
NEW QUESTION # 158
How many 42KW air conditioners can the FusionModule2000 integrated power distribution cabinet support at most?
- A. 4 units
- B. 5 units
- C. 3 units
- D. 2 units
Answer: B
NEW QUESTION # 159
Each socket of rPDU in FM2000 supports independent switching.
- A. False
- B. True
Answer: A
NEW QUESTION # 160
NetCol5000-CO30H row-level chilled water precision air conditioning fans can be maintained online, and a separate power-off switch can be provided for each fan to avoid safety hazards caused by direct live maintenance.
- A. True
- B. False
Answer: A
NEW QUESTION # 161
The UPS5000E power module adopts a fan fault-tolerant design. When one of the fans is damaged, how much load can the power module still carry?
- A. 0.5
- B. 0.6
- C. 0.3
- D. 0.25
Answer: A
NEW QUESTION # 162
A project requires the management system to access a third-party generator set, two smart meters (same model), and two precision air conditioners (same model). How many third-party equipment access fees does the management system need to report?
- A. 0
- B. None of the above
- C. 1
- D. 2
Answer: D
NEW QUESTION # 163
For cabinets (racks) arranged in rows, when their length exceeds (), additional channels should be added between two channels, and channels should be set up at both ends: when the distance between two channels exceeds (), channels should be added directly between the two channels.
- A. 6m, 20m
- B. 6m, 15m
- C. 8m, 15m
- D. 8m, 20m
Answer: B
NEW QUESTION # 164
The NetEco6000 management system can provide cooling and power system monitoring. Which of the following functions can it provide? (Multiple choice)
- A. None of the above
- B. Supports displaying key equipment indicators on the power distribution topology map, making it easier for users to understand the operating status of the system and important nodes
- C. Can provide a chilled water system topology diagram to show the operating status of the entire system
- D. It can provide a power distribution system topology diagram, showing the power distribution system diagram of the entire computer room
Answer: B,C,D
NEW QUESTION # 165
What is the core idea of Huawei's icooling concept?
- A. Refrigeration
- B. Collaborate with Apple to solve refrigeration problems
- C. Control the air conditioner via iPhone
- D. LOL1L2 layer linkage, faster demand and more accurate feedback
Answer: D
NEW QUESTION # 166
UPS2000-G has a graded power-off function. When overloaded, it shuts down secondary loads to eliminate overload and ensure power supply quality. When power is off, it shuts down secondary loads to extend the backup time of important loads.
- A. True
- B. False
Answer: A
NEW QUESTION # 167
......
Huawei H19-402_V1.0 (HCSP-Presales-Data Center Network Planning and Design V1.0) Exam is one of the most sought-after certifications for IT professionals who want to specialize in data center network planning and design. H19-402_V1.0 exam is designed to test the candidate's knowledge and skills in various areas such as data center network design principles, network architecture, virtualization, storage networking, and security. HCSP-Presales-Data Center Network Planning and Design V1.0 certification is recognized globally and is a great way to demonstrate your expertise in data center network planning and design.